microAir Turn-Q Rotational Mattress
Product ID: BB9612000 Standard Width (84"L x 37"W x 8"H)
Therapeutic mattress for Stage III and IV, or multiple Stage II pressure ulcers.
Turn-Q Mattress:
The Turn-Q Plus is a deep flotation, true low air loss therapy system that can directly replace specialty hospital beds. The Turn-Q is portable, and readily attached to most hospital and nursing home beds. The Turn-Q Plus replaces the mattress on standard medical beds. It provides continuous flotation in all turning modes assuring that patients do not “bottom out” on a hard bed surface. The mattress will maintain the patient on an air flotation surface during a power failure. When power is restored, the system will resume operation without intervention by the care giver.
The microAir Turn-Q mattress is capable of turning/rotating the patient up to 40 degrees. The pump system is programmable so you can set or change rotation intervals. This eliminates caregivers having to manually re-position the patient through the day or night.
The microAIR Turn-Q Plus combines the benefits of lateral rotation, true low air loss and pressure relief in a single portable system. The system's two selectable turning angles provide the ability to bilaterally rotate patients a full or partial turn. This reduces the risk of complications associated with immobilization. In addition, the Turn-Q Plus offers unmatched patient comfort and pressure ulcer management by regulating heat and moisture, relieving pressure and reducing friction and shear. The process is automatic and completely adjustable.
The user-friendly control panel allows the system to be customized to meet individual needs. New features like quick CPR deflate, panel lockout, low pressure alarm, and 24-hour backup help improve patient care. As with all microAIR products, the Turn-Q Plus is easy to install on a standard hospital bed and simple to operate and maintain. In fact, the Turn-Q Plus by Invacare benefits everyone. It enhances patient care quality and increases caregiver productivity, all at an economical cost.
Mattress only, does not include hospital bed.
- Automatic turning and static floatation modes
- Easy-to-understand, caregiver-friendly membrane control panel
- Bilaterally turns resident up to 40-degrees at preset intervals of 30, 60, or 90 minutes
- Auto-firm feature inflates the mattress to maximum firmness to facilitate resident handling
- Automatic Auto-firm mode shut-off if the unit is left unattended for 30 minutes or more
- Resident weight adjustable from 75-500 lbs
Code Approval:
|
UL544, CA106
|
Dimensions:
|
Standard
mattress: 84"L x 37"W x 8"H Narrow mattress: 84"L x 32"W x 8"H
|
Electrical:
|
Power: 115 vac, 50/60 Hz, 2A Leakage current: less than 100
microamps
|
Product Weight:
|
Mattress:
25 lb Power unit: 30 lb
|
Product Weight Capacity:
|
500 lb
|
Warranty:
|
Mattress: 6
months Power unit: 2 years
|
Detailed Specifications for Turn-Q Plus:
AIR TUBES
|
|
Washable:
|
Yes
|
Waterproof:
|
Yes
|
Number:
|
8 cylindrical tubes, One (1) lower mattress
|
|
|
Pressure
Sections:
|
Two (2) side, Three (3) left, Three (3) right, One (1)
lower
|
|
|
Tube Seam
Bonding:
|
RF Welded
|
|
|
PATIENT/MATTRESS INTERFACE
|
|
Vapor Permeable:
|
Yes
|
|
|
FILTERS
|
|
Air Filter:
|
Yes
|
|
|
WEIGHTS/CAPACITY
|
|
Patient Weight:
|
500 lbs. (227) kg
Maximum
|
System Weight:
|
Power Unit: 32 lbs.
14.5 kg
|
|
Matress: 28 lbs. 13.0
kg
|
|
Total: 60 lbs. 27.5 kg
|
|
|
AIR BLOWER
|
|
Service Life
(est.):
|
24,000 hrs.
|
|
|
DIMENSIONS
|
|
Mattress:
|
82 x 37 in. 208 x 94 cm
Standard Width
|
|
|
MATTRESS SANITIZATION
|
|
Fluid Entrapment:
|
No (Seamless)
|
Detergent.
Resist:
|
Yes
|
|
|
ELECTRICAL
|
|
Power:
|
115 VAC 50/60 Hz, 2A
(Operating)
|
|
|
SAFETY
|
|
Listing Agency:
|
Underwriters
Laboratories
|
Listing
Specification:
|
UL 544
|
Fire:
|
Cal 106
|
|
|
The microAIR Turn-Q Plus combines the benefits of lateral rotation, true low air loss and pressure relief in a single portable system. The system's two selectable turning angles provide the ability to bilaterally rotate patients a full or partial turn. This reduces the risk of complications associated with immobilization. In addition, the Turn-Q Plus offers unmatched patient comfort and pressure ulcer management by regulating heat and moisture, relieving pressure and reducing friction and shear. User-Friendly Controls: - Graphic displays and digital inputs make setup and operation simple
- Panel lockout secures the panel from accidental setting changes
- 24-hour backup provides air flotation when electrical power is interrupted
- Low pressure alarm alerts the caregiver to low mattress pressure
- Direct weight input from 70 to 500 lb. ensures patients receive the correct level of support pressure
- Bar graph comfort range control makes it easy to further customize individual pressure adjustments to meet specific patient requirements
- Next turn display notifies caregiver of time remaining to next turn
- Control panel memory saves caregiver the time and inconvenience of trying to remember and reset system settings after power interruption
- Ambient light sensor dims panel lights in a darkened room so as not to disturb patient
- Auto firm mode eases patient handling for nursing procedures or bed entry/exit

Quick Patient Setup:- Use the (M) Auto-Firm Button. Press the Auto-Firm Button to engage auto firm. The Mattress will become firm for nursing procedures. An indicator lights to notify the bed is in Auto-Firm mode. A timer will cancel auto firm in 30 Minutes. Should the nurse be called away, an unattended patient will not be left on a firm surface.
- Set the patient weight with the Weight selection buttons (G).
- Press the “Center” static Turning Mode button (I).
- Place the patient on the bed.
- Center the patient on the bed from side-to-side and head-to-foot.
- Use a regular pillow under the head for comfort and to prevent the head from rolling excessively.
- Raise side rails.
- Press the desired Turning Mode button (O).
- Press the Full Turn Range button (J).
- Set the Turn Interval time with the up/down buttons (L).
- If the patient feels the bed is too soft/hard press the up/down Comfort Range buttons accordingly (H).
Rotational Mattress turns patient up to 40 degrees at programmable time-interval.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Product Features
- Therapeutic for Stage III and IV, or multiple Stage II pressure ulcers
- Lateral rotation automatically turns patients up to 40 degrees to reduce the risk of pulmonary and other serious medical complications associated with immobilization
- Seven selectable turning modes (3 fixed and 4 automatic variable turning positions), provide flexibility to meet individual patient needs
- Six turning intervals between 4 minutes and 2 hours meet prescribed turning schedules
- Low air loss regulates skin moisture and temperature, an important factor in preserving skin integrity for the prevention of pressure ulcers
- 500-lb weight capacity
 User-Friendly Controls This easy-to-use membrane control unit makes system set-up and operation simple and trouble-free. Loaded with features not found in other mattress replacements including, a power button with an LED indicator that informs the operator if the unit is in standby or operating mode. In addition, the control unit easily attaches to the bed's footboard.
Turn-Q Mattress replacement Parts
Download Manufacturer's Glossy
Owner's Manual
See also: Invacare microAir Lateral Rotation Mattress model MA95Z
|
|
 |
 |
 |
 |

|