TENS Unit 5 Mode 100mA
Model: TENS 7000
Federal law (USA) restricts this device to sale by or on the order of a physician.
Effective treatment with 100mA output. Unit has Dual Channels, Timer and Compliance Meter.
Operates in 5 modes:
- Burst
- Normal
- Modulation
- Strength Duration 1
- Strength Duration 2
TENS Unit is easy to operate with adjustable pulse width and pulse frequency.
Kit includes everything you'll need.
Channels: Dual isolated channels with 5 modes of operation.
Wave Form: Asymmetric bi-phasic square pulse.
Operating Modes: B(Burst), N(Normal), M(Modulation), SD1 (Strength Duration), SD2
Burst Mode: Burst rate: Adjustable, 0-5 – 5Hz
Pulse width adjustable, 50~300µS
Frequency fixed = 100 Hz
Normal Mode:The pulse rate and pulse width are adjustable. It generates continuous stimulation based on the setting value.
Modulation Mode:Modulation mode is a combination of pulse rate and pulse width modulation.
The pulse rate and width are automatically varied in a cycle pattern. The pulse width is decreased by 50% from its original setting in 0.5 second, then the pulse rate is decreased by 50% from its original setting in 0.5 second. Total cycle time is 1 second. In this mode, pulse rate (2-150Hz) and pulse width (50-300µS) are fully adjustable.
SD1 Mode:The SD1(Strength-Duration) mode consists of automatic modulation intensity and pulse width in 40% range. The intensity is always increasing while the pulse width is decreasing and vice versa. The intensity is decreased by 40% while the pulse width is increased by 40% in 5 seconds. In the next 5 seconds, the intensity is increased by 40% while the pulse width is decreased by 40%. Total cycle time is 10 seconds. Pulse rate (2~150Hz) and pulse width (50 ~300µS) are fully adjustable.
SD2 Mode:The SD2(Strength-Duration) mode consists of automatic modulation intensity and pulse width in 70% range. The intensity is always increasing while the pulse width is decreasing and vice versa.The intensity is decreased by 70% while the pulse width is increased by 70% in 5 seconds. In the next 5 seconds, the in tensity is increased by 70% while the pulse width is decreased by 70%. Total cycle time is 10 seconds. Pulse rate (2~150Hz) and pulse width (50 ~300µS) are fully adjustable.
Timer:Adjustable, from 5 to 60 minutes or Continuous. Adjustable in 5 minutes each step. Treatment time countdown automatically.
Specifications:Channels: | Dual Channels, Isolated between channels |
Output: | 100mA |
Wave Form: | Asymmetric biphasic square pulse |
Amplitude: | Adjustable, 0-100 mA peak into 500 ohm load each channel.
|
Pulse Width: | Variable, 50-3000 microseconds, 10µS/step, adjustable. |
Frequency: | 2 to 150 Hz, adjustable. |
Voltage: | 0 - 50V (Load: 500 ohm) |
Modes: | 5 modes |
Power Source: | 9V DC square shape battery |
Size: | 10.1cm(L) x 6.1cm(W) x 2.45cm(H) |
Weight: | 150 grams (including battery). |
Warranty: 3 Years